Skip to content

Arinite is Your One-Stop Shop for Global Health and Safety Compliance For Local Expertise

Traffic Routes, Doors and Escalators: the 10 Rules Offices Never Check

A
Arinite Health & Safety Consultants
November 29, 2026
10 min read
Traffic Routes, Doors and Escalators: the 10 Rules Offices Never Check

Ask an office manager whether the traffic route rules apply to them and the answer is usually no, on the reasonable basis that there are no forklifts in a law firm. It is the wrong answer, and the reason is a definition.

A traffic route in the Workplace Regulations is a route for pedestrian traffic, vehicles or both, and it expressly includes any stairs, staircase, fixed ladder, doorway, gateway, loading bay or ramp. Every staircase and every doorway in your building is a traffic route. The duties attach whether or not a vehicle ever comes near the place.

Then there is a short list of door requirements that nobody inspects. Sliding doors need a device to stop them leaving the track. Upward opening doors need something to stop them falling back. Powered doors need anti-trap features and a way of working when the power goes. These are stated requirements, not best practice.

Here are the 10 rules, each with its provision.

1. The workplace must be organised for safe circulation

Regulation 17(1) of the Workplace (Health, Safety and Welfare) Regulations 1992 requires every workplace to be organised in such a way that pedestrians and vehicles can circulate in a safe manner. It is a duty about the arrangement of the place, not about signage or training.

2. A traffic route includes your stairs and doorways

The Approved Code of Practice records the regulation 2 definition: a traffic route is a route for pedestrian traffic, vehicles or both, and includes any stairs, staircase, fixed ladder, doorway, gateway, loading bay or ramp. This is the provision that brings an entirely pedestrian office inside regulation 17.

3. Suitable, sufficient in number, suitably positioned, big enough

Regulation 17(2) requires traffic routes to be suitable for the persons or vehicles using them, sufficient in number, in suitable positions and of sufficient size. Four separate tests, and "sufficient in number" is the one that bites when a floor is reconfigured and circulation gets squeezed to one route.

4. Separation from doors and from routes leading onto them

Regulation 17(3)(b) requires sufficient separation of any traffic route for vehicles from doors or gates, or from pedestrian traffic routes which lead onto it, and regulation 17(3)(c) requires sufficient separation where vehicles and pedestrians share a route. In an office estate this is the car park entrance, the service yard and the point where the fire exit discharges.

5. Routes must be indicated where necessary

Regulation 17(4) requires all traffic routes to be suitably indicated where necessary for reasons of health or safety. The qualifier matters: this is not a requirement to line paint every corridor, but it does mean a decision has to have been taken and recorded.

6. Two way doors need a clear view of both sides

Regulation 18(2)(e) requires any door or gate capable of being pushed open from either side to be constructed so as to provide, when closed, a clear view of the space close to both sides. ACOP paragraph 176 adds that conventionally hinged doors on main traffic routes should also have viewing panels, and that panels should be positioned so a person in a wheelchair can be seen from the other side.

7. Sliding doors need a device and a retaining rail

Regulation 18(2)(a) requires any sliding door or gate to have a device to prevent it coming off its track during use. ACOP paragraph 177 goes further and calls for a stop or other effective means, plus a retaining rail to prevent the door falling should the suspension system fail or the rollers leave the track. Two separate failures, two separate protections.

8. Upward opening doors need a counterbalance or ratchet

Regulation 18(2)(b) requires any upward opening door or gate to have a device to prevent it falling back. ACOP paragraph 178 names the usual solutions: an effective device such as a counterbalance or ratchet mechanism. Shutters on a service entrance or a post room are the common case.

9. Powered doors need anti-trap features and a power failure answer

Regulation 18(2)(c) requires any powered door or gate to have suitable and effective features to prevent it causing injury by trapping any person. Regulation 18(2)(d) then requires, where necessary for health or safety, that a powered door can be operated manually unless it opens automatically if the power fails. Automatic entrance doors and powered gates need one or the other, and most buildings have never been asked which.

10. Escalators need identifiable, accessible emergency stops

Regulation 19 requires escalators and moving walkways to function safely, to be equipped with any necessary safety devices, and to be fitted with one or more emergency stop controls which are easily identifiable and readily accessible. Easily identifiable and readily accessible are both tests the control has to pass, not just present.

The 10 rules at a glance

RuleProvisionWhat offices assume
Organised for safe circulationReg. 17(1)Only applies with vehicles
Stairs and doorways are routesReg. 2 definition, ACOP para. 150Route means a roadway
Four suitability testsReg. 17(2)One corridor is enough
Separation from doors and routesReg. 17(3)(b) and (c)Car park is the landlord's
Indicated where necessaryReg. 17(4)No decision recorded
Two way doors, clear viewReg. 18(2)(e), ACOP para. 176Panels at standing height only
Sliding doors, device and railReg. 18(2)(a), ACOP para. 177A stop is enough
Upward doors, falling backReg. 18(2)(b), ACOP para. 178Shutters never checked
Powered doors, trap and powerReg. 18(2)(c) and (d)No power failure answer
Escalator emergency stopsReg. 19Present but not identifiable

Rows two and three are the pair that change the scope of the exercise. Once stairs and doorways are traffic routes, regulation 17(2) applies to every floor of a purely pedestrian building, and the test "sufficient in number" becomes a real question after any reconfiguration. The fire route is not the answer either, because escape provision and everyday circulation are separate duties, as our note on fire exits and escape routes sets out.

Rows seven to nine are the cheapest findings on the list and the ones we most often raise. A retaining rail on a sliding door, a ratchet on a shutter and a manual release on a powered entrance are all small items that either exist or do not, and the answer is usually in the installation documentation nobody has opened since the fit out. Where deliveries arrive, the loading bay is itself a traffic route by definition, which is the point our note on deliveries and post rooms develops.

One correction worth making, because older guidance still gets this wrong. Regulation 13(1) to (4), the general duty about falls and falling objects, was revoked by the Work at Height Regulations 2005. What survives in regulation 13 is narrower: regulation 13(5) requires every tank, pit or structure where a person might fall into a dangerous substance to be securely covered or fenced so far as is practicable, regulation 13(6) requires secure fencing of traffic routes over or across such a structure, and regulation 13(7) defines dangerous substance to include anything likely to scald or burn, anything poisonous or corrosive, any fume, gas or vapour likely to overcome a person, and granular, free flowing or viscous substances in a dangerous quantity. If your file cites regulation 13 for working at height, it is citing a revoked provision.

Holding the circulation plan with its route count, the door and gate inventory with the device present against each type, the escalator stop control locations and the dates each was last checked in one place is the practical reason health and safety consultants and software work better as one system than as a set of installation manuals. Periodic health and safety audits then test it with one question: for each sliding, upward opening and powered door in the building, which device is fitted? The wider instrument sits in our note on the 15 duties in the Workplace Regulations, and a move resets the whole picture, as in office relocation.

The same circulation in your other countries

The pattern we see across multi country clients holds here too: the hazard is movement, the standard is the building code.

Britain is unusual in putting these requirements in health and safety law at all. In many of the systems we work in, door devices, escalator stop controls and circulation widths sit in the building code and are inspected on handover rather than audited during occupation. The protection is comparable, but the file it lives in is different, and that is where group standards fail.

The practical consequence is that a health and safety audit in another country may legitimately not look at these items, while a British inspector can. A group that relies on the local audit scope to tell it what matters will therefore have a gap in the UK entities rather than abroad, which is the opposite of the usual direction.

The workable split is a group standard that fixes the door and route inventory, with a local column for which code applies and who verifies it. The broader comparison sits in the key differences in international legislation and the complete global guide. In leased buildings the doors, stairs and escalators are usually landlord fabric while the duty is yours, as in coworking and serviced offices.

Where Arinite fits

What our health and safety consultants do here is inventory the things nobody has listed. We identify every traffic route on the definition rather than the assumption, which usually trebles the count, and test regulation 17(2) against the current layout rather than the original plan. We then walk the doors and gates and record, type by type, whether the required device is actually fitted: a track device and retaining rail on sliders, a counterbalance or ratchet on upward openers, anti-trap features and a manual or automatic power failure answer on powered doors, and viewing panels at a height that works for a wheelchair user. We check escalator stop controls against both tests in regulation 19. And we remove revoked citations from the file, because regulation 13 for falls is the most common one we still find. We support more than 1,500 businesses in over 50 countries, protecting more than 100,000 employees, with client retention above 95% over more than 15 years, concentrated in offices, legal, insurance, IT and software and education, where the fabric is leased and the devices were specified by someone else. For groups across several countries our global health and safety consultants and international health and safety consultants map the same inventory onto the local code.

One question for this week: how many sliding, upward opening and powered doors does your building have, and does anyone know which safety device is fitted to each? If nobody does, ask us for a free gap analysis and we will work through the ten rules for one building in a single conversation.

Share this article
A

Written by

Arinite Health & Safety Consultants

Health & Safety Expert at Arinite

Free Resources

Health & Safety Factsheets

Download our comprehensive library of expert guides, checklists, and templates.

Get Professional Help

Need Expert H&S Advice?

Our qualified consultants are ready to support your specific business needs.