Skip to content

Arinite is Your One-Stop Shop for Global Health and Safety Compliance For Local Expertise

Office Welfare: the 14 Rules and the Numbers the ACOP Sets

A
Arinite Health & Safety Consultants
November 29, 2026
10 min read
Office Welfare: the 14 Rules and the Numbers the ACOP Sets

Welfare is the part of the Workplace Regulations that gets summarised and then never checked. Everyone knows there have to be toilets, water and somewhere to eat. Very few offices can say how many of each they are supposed to have, or on what basis the number is calculated.

The numbers do exist, and they are specific. One cubicle and one washbasin up to five people. An additional toilet and washbasin for every 25 people above a hundred. A urinal counts as at least 600mm of urinal space. And the count is based on the maximum number of people likely to be in the workplace at any one time, which in a hybrid office is a different number from the headcount on the payroll.

Here are the 14 rules, with the provision and the figure behind each. Our note on the seven welfare requirements and the hybrid problem is the overview; this is the detail underneath it.

1. Sanitary conveniences, suitable and sufficient

Regulation 20(1) of the Workplace (Health, Safety and Welfare) Regulations 1992 requires suitable and sufficient sanitary conveniences at readily accessible places. Readily accessible is doing work here: a facility two floors away through a locked door is not.

2. Three conditions make them suitable

Regulation 20(2) provides that they are not suitable unless the rooms containing them are adequately ventilated and lit, they and their rooms are kept in a clean and orderly condition, and separate rooms are provided for men and women except where each convenience is in a separate room whose door can be secured from inside.

3. The mixed workplace table

The Approved Code of Practice Table 1 sets the minimum for workplaces used by both men and women: 1 to 5 people, one cubicle and one washbasin; 6 to 25, two of each; 26 to 50, three; 51 to 75, four; 76 to 100, five.

4. Counted on peak occupancy, per group

ACOP paragraph 197 states that the figure refers to the maximum number of workers likely to be in the workplace at any one time, and that where separate toilets are provided for a group, a separate calculation should be made for each group. It adds that more may be needed where breaks are taken at set times or workers finish together.

5. The men only alternative, and what a urinal means

ACOP paragraph 199 allows Table 2 as an alternative where toilets are used only by men: 1 to 15 men, one cubicle and one urinal; 16 to 30, two cubicles and one urinal; 31 to 45, two and two; 46 to 60, three and two; 61 to 75, three and three; 76 to 90, four and three; 91 to 100, four and four. A urinal may be an individual unit or a section of urinal space at least 600mm long.

6. And what happens above a hundred

ACOP paragraph 200 requires an additional toilet and washbasin for every 25 people above a total of 100, or fraction of 25. Where toilets are used only by men, an additional cubicle for every 50 men above 100 is sufficient. Growing offices cross this line without anyone recalculating.

7. Washing facilities, including showers where the work requires

Regulation 21(1) requires suitable and sufficient washing facilities at readily accessible places, including showers if required by the nature of the work or for health reasons. The trigger is the work, not the building's specification.

8. Located in the immediate vicinity

Regulation 21(2)(a) and (b) require washing facilities in the immediate vicinity of every sanitary convenience, whether or not provided elsewhere as well, and in the vicinity of any changing rooms required by the Regulations. Immediate vicinity is a stricter test than the same floor.

9. Water, soap and a means of drying, all three

Regulation 21(2)(c) to (e) require a supply of clean hot and cold, or warm, water which shall be running water so far as is practicable, soap or other suitable means of cleaning, and towels or other suitable means of drying. All three are separate requirements, and a broken dryer with no alternative is a breach rather than an inconvenience.

10. Wholesome drinking water, marked where necessary

Regulation 22(1) and (2) require an adequate supply of wholesome drinking water for all persons at work, readily accessible at suitable places and conspicuously marked by an appropriate sign where necessary for reasons of health and safety.

11. Cups unless it is a jet, and not in the toilets

Regulation 22(3) requires a sufficient number of suitable cups or other drinking vessels unless the supply is a jet people can drink from easily. ACOP paragraph 210 adds that taps should not be installed where contamination is likely and, so far as is reasonably practicable, should not be installed in toilets, which is where a surprising number of offices put the only drinkable tap.

12. Accommodation for clothing, with security

Regulation 23 requires suitable and sufficient accommodation for clothing not worn during working hours and for special clothing which is worn but not taken home. Where changing facilities are required, the accommodation must provide suitable security for the first category, and where necessary must avoid risks to health or damage to the clothing.

13. Rest facilities, rest rooms, and somewhere uncontaminated to eat

Regulation 25(1) requires suitable and sufficient rest facilities at readily accessible places. Regulation 25(2) requires, in a new workplace, extension or conversion, that these are in one or more rest rooms rather than rest areas, and requires suitable facilities to eat meals where food eaten in the workplace would otherwise be likely to become contaminated. Regulation 25(3) requires an adequate number of tables and adequate seating with backs, plus seating adequate and suitable for disabled persons at work.

14. Pregnant women, nursing mothers, and disabled workers

Regulation 25(4) requires suitable facilities for any person at work who is a pregnant woman or nursing mother to rest. Regulation 25A, added in 2002, requires that where necessary those parts of the workplace used or occupied directly by disabled persons at work, including in particular doors, passageways, stairs, showers, washbasins, lavatories and workstations, are organised to take account of them.

The 14 rules at a glance

RuleProvisionThe number or test
Sanitary conveniences providedReg. 20(1)Readily accessible
Suitability conditionsReg. 20(2)Lit, clean, separated
Mixed workplace minimumACOP Table 11 per 5, then per 25 band
Counted at peak, per groupACOP para. 197Maximum at any one time
Men only alternativeACOP Table 2 and para. 199Urinal means 600mm
Above 100 peopleACOP para. 200Extra WC and basin per 25
Washing facilities and showersReg. 21(1)Showers if work requires
LocationReg. 21(2)(a) and (b)Immediate vicinity
Water, soap, dryingReg. 21(2)(c) to (e)Three separate duties
Wholesome drinking waterReg. 22(1) and (2)Marked where necessary
Vessels, and tap sitingReg. 22(3), ACOP para. 210Not in toilets if practicable
Clothing accommodationReg. 23Security where changing needed
Rest and eating facilitiesReg. 25(1) to (3)Rest rooms if new or converted
Pregnancy, nursing, disabilityReg. 25(4) and 25ANamed facilities and areas

Rows three to six are where the audit findings come from, and row four is why. The count is based on the maximum number likely to be present at any one time, so an office that reduced its desk count after moving to hybrid working has not necessarily reduced its obligation, because the relevant figure is the busiest day rather than the average. Equally, a firm that has grown past a hundred people needs an extra cubicle and basin for every 25 beyond that, and nobody tends to notice the moment it crosses.

Row eleven is the one that makes people check their own kitchen. If the only tap anybody actually drinks from is inside a toilet, the ACOP says it should not be there so far as is reasonably practicable, and that is a cheap thing to correct before someone asks.

Row fourteen is the least implemented. Regulation 25(4) is a specific, named requirement for a pregnant woman or nursing mother to rest, not a general welfare aspiration, and it pairs with the assessment trigger set out in our note on pregnancy risk assessment. Regulation 25A then names the specific parts of a building that must be organised for disabled workers, which is the statutory companion to the work covered in our note on access audits.

Holding the peak occupancy figure, the facility count against the tables, the shower trigger assessment, and the named rest arrangements in one place is the practical reason health and safety consultants and software work better as one system than as a facilities spreadsheet. Periodic health and safety audits then test it with one question: what is your peak occupancy and does the facility count match the table for it? The wider instrument is covered in our note on the 15 duties in the Workplace Regulations.

The same facilities in your other countries

The pattern we see across multi country clients holds here too: the facilities are expected everywhere, the ratios are not.

Britain is unusual in putting the ratios in an Approved Code of Practice rather than in the Regulations. That gives flexibility, but it also means the figures are easy to miss entirely: an employer reading only the Regulations finds "suitable and sufficient" and no numbers at all.

Several systems we work in set the ratios in the instrument itself, sometimes with different bands, and some add requirements Britain does not have. The practical effect is that a group facilities standard written to the British tables is defensible here and arbitrary elsewhere.

The workable split is a group standard fixing the peak occupancy method and the facility types, with a local column for the ratios. The broader comparison sits in the key differences in international legislation and the complete global guide. In leased buildings the facilities are shared and the count is rarely anyone's job, as in coworking and serviced offices.

Where Arinite fits

What our health and safety consultants do here is count. We establish the peak occupancy figure properly rather than using headcount or desk count, run it against both ACOP tables including the above hundred rule, and tell you in writing whether the provision meets the minimum and by what margin. We check the location tests, because facilities in the immediate vicinity of every convenience is a stricter requirement than most buildings satisfy, and we test the shower trigger against the actual work rather than the building spec. We also make sure the named requirements in regulations 25(4) and 25A exist as identified arrangements rather than as a line in a policy. We support more than 1,500 businesses in over 50 countries, protecting more than 100,000 employees, with client retention above 95% over more than 15 years, concentrated in offices, legal, insurance, IT and software and education, where shared facilities and fluctuating occupancy make the count genuinely uncertain. For groups across several countries our global health and safety consultants and international health and safety consultants apply the local ratios to the same method.

One question for this week: what is the maximum number of people likely to be in your office at any one time, and how many cubicles and washbasins does the table require for that figure? If you cannot answer both halves, ask us for a free gap analysis and we will work through the fourteen rules for one site in a single conversation.

Share this article
A

Written by

Arinite Health & Safety Consultants

Health & Safety Expert at Arinite

Free Resources

Health & Safety Factsheets

Download our comprehensive library of expert guides, checklists, and templates.

Get Professional Help

Need Expert H&S Advice?

Our qualified consultants are ready to support your specific business needs.