A facilities director in Frankfurt receives a request from the group's American headquarters: please send over the facility response plan for the German sites. She has a fire safety file, an alarm plan, operating instructions for the diesel tanks and a first aid roster. She has nothing with that title, and no idea whether she is missing a legal document or a translation.

She is missing a translation. "Facility response plan" is a term of art in United States environmental law, with a precise meaning that covers very few buildings. Outside the US the same words are used loosely for any site emergency plan, and the legal duties underneath are organised differently in every country.

That gap matters to any organisation running sites in more than one jurisdiction. Ask for the wrong document and you get either nothing or a file that satisfies no regulator. Ask the right question, which emergency plans does the law of this country require for this site, and the answer is usually three layers: a plan for people, a plan for stored substances, and a plan for major accidents.

This article sets out those three layers in three countries. Nine plans, in a grid, so that a request sent from one country can be answered properly in another.

United States

1. The Facility Response Plan itself

In US law the term belongs to the Environmental Protection Agency's oil pollution rules under the Clean Water Act. The EPA's overview of the FRP rule describes a plan that demonstrates a facility's preparedness to respond to a worst case oil discharge, required by 40 CFR 112.20.

Very few facilities need one. Under the EPA's applicability criteria, a facility may pose substantial harm if it has total oil storage of 42,000 gallons or more and transfers oil over water to or from vessels, or has total oil storage of 1 million gallons or more and meets one of four conditions: insufficient secondary containment, a location where a discharge could injure fish, wildlife and sensitive environments, a location where a discharge would shut down a public drinking water intake, or a reportable discharge of 10,000 gallons or more within the past five years.

An office does not come close. A large data centre campus with extensive generator fuel storage is the realistic case in the sectors we work with, and it should run the self identification test and keep the result. In March 2024 the EPA also finalised parallel planning requirements for worst case discharges of hazardous substances, so the question is no longer only about oil.

2. The spill prevention plan beneath it

Below the FRP sits the Spill Prevention, Control and Countermeasure plan, part of the same oil pollution regulation and triggered at far lower storage volumes. It is a prevention document: containers, containment, inspections and procedures. Many facilities that will never need an FRP do need this, including sites whose only oil is generator diesel. The two are regularly confused, and the confusion runs in the expensive direction, with firms commissioning a response plan they do not need while lacking the prevention plan they do.

3. The Emergency Action Plan for people

The plan most US workplaces actually need is the OSHA emergency action plan under 29 CFR 1910.38: written, kept in the workplace and available to employees, covering evacuation and the people designated to assist. We have published a full emergency action plan template for offices. When an American colleague asks an office for its facility response plan, this is almost always the document they mean.

Germany

Germany has no single instrument called a facility response plan. The same three layers exist, in three different laws.

4. Emergency measures under the Arbeitsschutzgesetz

Section 10 of the Arbeitsschutzgesetz requires the employer to take the measures necessary for first aid, firefighting and the evacuation of employees, according to the type of workplace, the activities and the number of employees, and to take account of other persons present. The employer must ensure the necessary connections to external services are in place, and must designate the employees who take on first aid, firefighting and evacuation tasks, in numbers, training and equipment proportionate to the workforce and the particular hazards. The works council must be heard before those designations are made.

This is the people layer, and it applies to every employer. In practice it is delivered through the documents a German site already holds: the escape and rescue plan, the fire safety rules and the alarm plan. Our guide to tech and AI health and safety in Germany covers the wider system those sit in.

5. The operating instruction with its Notfallplan

For stored substances the relevant law is the ordinance on installations handling substances hazardous to water, the AwSV. Section 44 requires the operator to hold an operating instruction that contains a monitoring, maintenance and emergency plan and sets out immediate measures to prevent harm to waters. The plan must be agreed with the bodies involved in it. Operating staff must be instructed before starting work and at least once a year, and the instruction must be documented.

There are exemptions, including installations in the lowest hazard level and heating oil consumer installations, which instead require a prescribed information sheet to be displayed. A diesel tank serving standby generators therefore needs classifying before anyone can say which duty applies. This is the nearest German equivalent to the American spill plans, and it is the document most often missing when a group audits its German sites.

6. Alarm and hazard prevention plans under the Störfall-Verordnung

The major accident layer is the Störfall-Verordnung, the twelfth ordinance under the Federal Immission Control Act. Section 10 requires the operator of an upper tier establishment to draw up internal alarm and hazard prevention plans and to give the authority the information needed for external plans. Employees must be consulted on the content and instructed at least every three years, and the plans must be reviewed and tested at intervals of no more than three years.

Few of our clients' sites reach those thresholds. The ones that might are large battery storage, chemical stores and some laboratory or manufacturing operations.

United Kingdom

7. Procedures for serious and imminent danger

The people layer in Great Britain is regulation 8 of the Management of Health and Safety at Work Regulations 1999, which requires every employer to establish appropriate procedures to be followed in the event of serious and imminent danger and to nominate a sufficient number of competent persons to implement evacuation. Article 15 of the Regulatory Reform (Fire Safety) Order 2005 says the same for fire. Neither prescribes a document title, which is why British sites hold an emergency plan, a fire emergency plan or an evacuation procedure, and rarely anything called a response plan.

8. Oil storage: containment first, plan second

For stored oil in England the Control of Pollution (Oil Storage) (England) Regulations 2001 take a different approach from the American one. They apply to oil stored on any premises in containers above 200 litres, with exceptions including containers inside a building or wholly underground, and they regulate the engineering: a container of sufficient strength and integrity, within secondary containment holding at least 110% of the container's capacity. They do not require a response plan as such. A British site therefore answers the spill question with a bund and an inspection record, supported by a spill procedure adopted as good practice or required by an environmental permit.

9. The COMAH internal emergency plan

The major accident layer is the Control of Major Accident Hazards Regulations 2015. Regulation 12 requires every operator of an upper tier establishment to prepare an internal emergency plan specifying the measures to be taken inside the establishment, and to review, revise where necessary and test it at suitable intervals not exceeding three years. The British and German regimes share that three year cycle because both implement the same European directive.

The nine at a glance

LayerUnited StatesGermanyUnited Kingdom
PeopleEmergency Action Plan, 29 CFR 1910.38Arbeitsschutzgesetz s.10MHSWR reg 8 and Fire Safety Order art 15
Stored substancesSPCC plan under the oil pollution regulationAwSV s.44 operating instruction with emergency planOil Storage Regulations 2001: containment, with a spill procedure
Major accidentsFacility Response Plan, 40 CFR 112.20Störfall-Verordnung s.10COMAH 2015 reg 12

What this means for a multi-site employer

Three practical points come out of the grid.

Stop exporting document titles. A group standard that says every site shall hold a facility response plan produces confusion in Germany and Britain, and misdescribes most American sites too. A standard that says every site shall hold a current plan for people, an assessment of stored substances and a recorded decision on major accident thresholds can be met everywhere, in each country's own form.

Classify the fuel before writing the plan. Generator diesel, heating oil and battery systems are where office and technology estates meet these regimes. The answer depends on volume, location and containment, and it differs in each country. A site list with stored volumes against each national threshold is the single most useful page in the file.

Test what you have. Every regime above expects the plan to be exercised, and the major accident regimes say so with a number. A plan nobody has rehearsed is the common finding, as our guide to fire drills explains, and the same gap appears in business continuity planning.

Give each layer an owner. The people layer usually belongs to whoever runs health and safety. The substances layer tends to fall between facilities, the landlord and an environmental adviser, and the major accident decision often belongs to nobody because everyone assumes the site is too small to be caught. In leased buildings the tanks may not even be yours, in which case the question becomes what the landlord's plan says and whether you have seen it. A named owner for each layer at each site, with the landlord's documents on file where the plant is theirs, closes most of the gaps we find. It also means that the next request from head office reaches someone who knows which document is being asked for and can answer in a day instead of a month.

Keeping the site list, the thresholds, the plans and the exercise dates in one register is the kind of task health and safety consultants and software handle well together, because the failure is rarely a missing plan and usually a plan nobody can find or date. Our health and safety audits check each site against its own country's layer, not against a head office template.

Where Arinite fits

Arinite is a firm of health and safety consultants working across borders, so translating one country's requirement into another's is routine for us. For emergency planning that means establishing which of the three layers applies at each site, preparing or reviewing the people layer directly, and identifying where an environmental or major accident specialist is needed for the other two. We say so plainly when a question, such as an EPA submission or a Störfall classification, sits outside our remit.

We have worked this way for more than 15 years, with over 1,500 businesses, across more than 50 countries and over 100,000 employees, and we retain more than 95% of the clients who start with us. Our international health and safety consultants support teams in the United States, Germany and the United Kingdom, and our global health and safety consultants work with office and AI and data operators whose estates span all three.

If head office asked each of your sites for its facility response plan tomorrow, would every site send back the right document for its own country?

Share this article
A

Written by

Arinite Health & Safety Consultants

Health & Safety Expert at Arinite

Free Resources

Health & Safety Factsheets

Download our comprehensive library of expert guides, checklists, and templates.

Get Professional Help

Need Expert H&S Advice?

Our qualified consultants are ready to support your specific business needs.